x
Our website uses cookies. By using the website you agree ot its use. More information can be found in our privacy policy.

Additional Remarks

  • The modification of the  *CONTROL cards of the dummy file may have an influence on the performance and robustness of the model. Therefore the *CONTROL cards of the dummy model are proposed for simulations with the seat model as well.
  • In case modifications in the control cards are needed for the seat model, we offer to run a subset of the validation runs with the modified control cards to evaluate the influence. Please contact your local support for details.
  • All nodes have a connection to an element except the third beam nodes of all beam elements.
  • The model is free of initial penetrations
  • The Version 4.0.1 of the BioRID provides parameters to scale the joint friction for all limbs. As default a '1 g' adjustment of the joints is included. The user is now able to increase or decrease the friction values of the joints. The scale factors are used for the left and right hand side assemblies. So it is not possible to scale left and right assembly differently.

 

Parameter name Joint
sfankl Scale factor ankles
sfknee  Scale factor knees
 sfuleg  Scale factor upper legs
 sfyoke  Scale factor yokes
 sfuarm  Scale factor upper arms
 sflarm  Scale factor lower arm
 sfelbo  Scale factor elbow
 sfhawr  Scale factor wrist

 

  • One more additional parameter has been defined in the model. It is used to switch off the dynamic relaxation of the model. swrelax=1 means on and swrelax=0 means off.
  • The validation of the model has been done based on all tests which are shown in the manual. Goal of the validation process is to get a model with physical definitions as close as possible to the test results.  It might be possible that there are loading conditions which are not observed until now in the validations test and the validation does not fit to these new unknown conditions. Due to this the user is responsible for his own results.